Graco E-Flo 333587D Operation page 61

Iq dispense system
Table of Contents

Advertisement

Error
Location Type
MMUX
ADM
Advisory
MAD_
Pump
Advisory
MBD_
Pump
Advisory
MLC_
Pump
Advisory
MLD_
Pump
Advisory
MED_
Pump
Advisory
MG2_
Pump
Advisory
MG3_
Pump
Advisory
P1C_
Pump
Alarm or
P2C_
Deviation
(user
selectable)
333587D
Error
Error Name
Description
USB Log 90%
One or more
Full
USB log is 90%
full.
Maint. Due Pump
Maintenance
P_
due for pump
Maint. Due Driver
Maintenance
P_
due for driver
Rebuild Platen
Maintenance
Seals P_
due for platen
seals
Maint. Due
Maintenance
Platen Valve P_
due for platen
valve
Maint. Due
Maintenance
Dispense Valve
due for
P_
dispense valve
Low Filter
Low filter
Pressure P_
pressure drop
detected
High Filter
High filter
Pressure P_
pressure drop
detected
Low Pressure P_
Measured
outlet pressure
less than
desired outlet
pressure minus
tolerance
Cause
Solution
Data in the jobs or
Download the data or disable USB errors.
events log has not
been downloaded
recently and logs
are nearly full
The number of
Perform desired maintenance and reset the
pump cycles since
pump cycles in the setup screen.
last reset has
exceeded the
maintenance limit
set
The number of
Perform desired maintenance and reset the
driver cycles since
driver cycles in the setup screen.
last reset has
exceeded the
maintenance limit
set
The number of
Rebuild the platen seals if desired and reset
replaced drums
the platen cycles in the setup screen.
since last cycles
reset has exceeded
the maintenance
limit set
The number of
Perform desired maintenance and reset the
platen valve cycles
platen valve cycles in the setup screen.
since last reset has
exceeded the
maintenance limit
set
The number of
Perform desired maintenance and reset the
dispense valve
dispense valve cycles in the setup screen.
cycles since last
reset has exceeded
the maintenance
limit set
The filter has an
Replace the fluid filter.
opening in it
There is a clog in
Clean out the manifold to reduce the
the manifold
pressure.
Incorrect pressure
Enter correct pressure tolerance percentage
tolerance
in setup screen.
Failed pressure
Check transducer, replace if failed.
transducer
No or insufficient
Increase material flow.
material flow
Restrictor not
Slowly close restrictor to build pressure.
closed enough
Troubleshooting
61