Graco E-Flo 333587D Operation page 64

Iq dispense system
Table of Contents

Advertisement

Troubleshooting
Error
Location Type
V4H_
AMZ
Alarm
V6H_
AMZ
Alarm
WBD_
Driver
Alarm
WMC_
Driver
Alarm
WMH_
Driver
Alarm
WMG0
Gateway
Alarm
WMN_
Driver
Alarm
WNG0
Gateway
Alarm
WSC_
Driver
Deviation
WSU0
ADM
Alarm
WSN_
Driver
Alarm
64
Error
Error Name
Description
High Voltage H_
The incoming
power is above
minimum
acceptable limit
Wiring Error H_
The wiring is
invalided from
what the AMZ
is expecting
Encoder
Encoder or hall
Hardware P_
sensor
disconnected
or failed to
commutate
motor
Control Board P_
Control board
reset due to an
exception in
software
Control Board
The power to
Off P_
the control
board has been
turned off
Gateway Error
Gateway error
Detected
detected;
includes any
error not
covered by a
more specific
error
Software
Software
Mismatch P_
mismatch
detected in the
motor control
board
Gateway Map
Missing or
Error
invalid gateway
map
Encoder
Encoder
Calibration P_
calibration
information not
found
USB
USB
Configuration
configuration
Error
file not
detected
Invalided Styled
Style flow rate
setpoint was
invalided when
trying to run
Cause
Solution
Incoming line to
For 3 phase with neutral have qualified
line voltage has
electrician verify neutral wire.
increased above
265V
Wrong wiring of the
Verify incoming power is wired to the
power source to
disconnect correctly per the manual.
the AMZ
Encoder
Disconnect pump from AC power. Verify
disconnected or
encoder cable is properly connected. If so,
faulty
replace encoder.
Invalid software
Cycle the power to the pump to reset the
state
driver software.
Software bug
Update software to the latest available on
help.graco.com.
Disconnected
Turn on the disconnected switches.
switches
---
---
Hot board and cold
Update the driver control board software to
board have
the latest available on help.graco.com.
different software
versions
Missing or invalid
Install map in gateway.
gateway map
Encoder not
Perform encoder calibration through the
calibrated before or
setup screens of the ADM.
calibration
information deleted
USB configuration
Update software to the latest available on
file not loaded or
help.graco.com.
was deleted
The style flow rate
Place a desired flow rate in the style
setpoint was zero
definitions page.
333587D