Technical data
HP4a with 60 Hz operation
Type
Minimum pump capacity at maximum back
pressure
bar
psi
250130
25*
362
250190
25*
362
250250
25*
362
250350
25*
362
160210
16*
232
160300
16*
232
160400
16*
232
160550
16*
232
100330
10
145
100480
10
145
100635
10
145
100880
10
145
70465
6
102
70670
6
102
70890
6
102
71230
6
102
13.2

Metering reproducibility

76
The suction lift / suction pressure applies to filled suction lines and filled
liquid end - when installed correctly.
Maximum
stroke rate
l/h
gph
Strokes/min m water
155
40.9
86
230
60.8
124
300
79.3
164
420
111.0
225
250
66.0
86
360
95.1
124
480
126.8
164
660
174.4
225
400
105.7
86
580
153.2
124
760
200.8
164
1050
277.4
225
560
147.9
86
805
212.7
124
1070
282.7
164
1450
383.0
225
* Maximum back pressure for TTT, PPT and PCT material versions: 10
bar!
All figures refer to water at 20 °C.
Priming lift / priming pressure (dry) determined for empty suction line and
empty liquid end and as well as clean and moistened valves (the figures
are lower with valve springs).
The suction lift / suction pressure applies to filled suction lines and filled
liquid end - when installed correctly.
Data
Reproducibility
* for measurements taken under constant conditions, minimum 10% stroke
rate and water at 20 °C - when installed correctly and with a back pressure
of at least 1.5 bar
suction lift
Permis‐
Connector size
sible pri‐
ming pres‐
sure,
suction
side
bar
G-DN
column
3 m
1 bar
G1 1/2-DN25
3 m
1 bar
G1 1/2-DN25
3 m
1 bar
G1 1/2-DN25
3 m
1 bar
G1 1/2-DN25
3 m
1 bar
G1 1/2-DN25
3 m
1 bar
G1 1/2-DN25
3 m
1 bar
G1 1/2-DN25
3 m
1 bar
G1 1/2-DN25
3 m
1 bar
G 2" – DN32
3 m
1 bar
G 2" – DN32
3 m
1 bar
G 2" – DN32
3 m
1 bar
G 2" – DN32
3 m
1 bar
G2 1/4-DN 40
3 m
1 bar
G2 1/4-DN 40
3 m
1 bar
G2 1/4-DN 40
3 m
1 bar
G2 1/4-DN 40
Value Unit
±1 % *