13.13 Heating cartridge

13.14 Filling volumes

13.14.1

Hydraulic oil

Use
Manufacturer
Standard
Mobil
Use
Manufacturer
Food
Mobil

13.15 Sound pressure level HP4a

Sound pressure level
* Ri ~ 1 kΩ
Cable colour
Polarity
blue
-
brown
+
Install the sensor according to the chapter "Installation,
electrical". Refer to its documentation.
Sensor name: NJ1.5-8GM-N.
Technical data - see enclosed operating instructions:
"ELMESS operating instructions liquid heater type NAHF11 ...; HRHF11".
Required amount of oil
Type
Single head ver‐
sion
HP 4:
approx. 5.5 l
Name
Mobilube 1 SHC *
* or comparative hydraulic oil
** 1 L
Name
SHC Cibus *
* or comparative hydraulic oil
** 1 L
Sound pressure level LpA < 75 dB in accordance with EN ISO
20361:2010-10
At maximum stroke length, maximum stroke rate, maximum back pressure
(water)
Double head
version
approx. 6.1 l
Viscosity class
Order no.
75W - 90
1006010**
Viscosity class
Order no.
220
1007664**
Technical data
Supplied
amount of oil
7.0 l
83