About this task
Initially, both receivers have the same IP address, ending by 44.4. This means you cannot connect
both receivers at the same time. To be able to use both, you need to change receiver 2 IP address
into 44.3.
Procedure
1. From the left side of the receiver page, click Hydrophones and from Rx/Tx turn all the
hydrophones off.
2. On the receiver, press the button
Note: If you pressed the button for too long and that the H3 LED lights up, press down
the button until it comes back to H1, then H2.
3. Disconnect, then reconnect receiver 2 to validate the change of IP address.
On the receiver page, the part H4-H5-H6 Module has a green check and the IP address ends by
44.3.
M6 - Mx computer System | V2 | Installation
and hold until the blue LED changes from H1 to H2.
| 41