REVO C
2PH from 1100A to 2100A
6.4 Output features 690V
Repetitive
Output
peak
Voltage
Current
reverse
range
voltage
(Ue)
(Uimp)
(up to
(A)
(V)
690V)
1100A
24÷690
2200
1400A
24÷690
2200
1600A
24÷690
2200
1800A
24÷690
2200
2100A
24÷690
2200
6.5 Environmental installation conditions
Ambient temperature
Storage temperature
Installation place
Altitude
Humidity
Pollution Level
6.6 Derating Curve and Thermal conditions
The nominal current of the units in specification are referred to continuous service at 40°C ambient temperature.
For higher temperature multiply the nominal current times derating coefficient K below represented:
l max = l nominal x K
For higher cabinet
temperature
(more than 50°C)
contact the producer
of the unit
Operation at ambient operating temperature above 40°C not covered by UL
Latching
Max peak
Leakage
current
one cycle
current
(10msec.)
(mAeff)
(mAeff)
(A)
700
36000
700
36000
700
36000
700
60000
700
60000
1,2
1
Derating
1
0,8
0,6
0,4
0,2
0
15
20
FUSE I2T
value
Frequency
Suggested
range
A2s (at
660V)
tp=10msec
(Hz)
300
1.900.000
47÷70
300
3.300.000
47÷70
300
3.900.000
47÷70
300
3.900.000
47÷70
300
3.900.000
47÷70
0-40°C (32-104°F) at nominal current.
Over 40°C -104°F use the derating curve (max 50°C).
-25°C to 70°C
-13°F to 158°F
Don't install at direct sun light, where there are conductive
dust, corrosive gas, vibration or water and also
in salty environmental.
Up to 1000 meter over sea level. For higher altitude
reduce the nominal current of 2% for each 100m over 1000m
From 5 to 95% without condense and ice
Up to 2nd Level ref. IEC 60947-1 6.1.3.2
1
1
1
1
25
30
35
40
CABINET TEMPERATURE °C
19
User's manual
Power
FANS
loss
(230Vac Standard)
Thyristor
(115Vac Option)
+ Fuse
I=Inom
N°
W
(W)
150
2698
2
(75 x 2 Fan)
300
3646
4
(75 x 4 Fan)
300
3722
4
(75 x 4 Fan)
300
4162
4
(75 x 4 Fan)
300
4722
4
(75 x 4 Fan)
0,9
0,8
45
50
55
®
m3/h
1560
(780 x 2 Fan)
3120
(780 x 4 Fan)
3120
(780 x 4 Fan)
3120
(780 x 4 Fan)
3120
(780 x 4 Fan)
Need help?
Do you have a question about the REVO C EXTENDED 2PH and is the answer not in the manual?