Setup Items and Default Values

Setup Items in Setting Mode and Their Default Values

Setup Item
Range > CH
Range > Mode
Range > Mode > Range
*Bias > CH
*Bias > Bias
*Bias > Bias
Calibration correction (/CC1 option)
Setup Item
Calibration > CH
Calibration > Calibration
Calibration > datums
Calibration > revise
Calibration > Decision
Setup Item
Alarm > CH
Alarm > Level
Alarm > Alarm
Alarm > Type
Alarm > Value
Alarm > Relay
Alarm > Relay number
Unit > CH
Unit > Unit
Chart
Clock
Aux > Trend
Aux > Zone > CH
Aux > Zone > Left, Right
*Aux > Partial > CH
*Aux > Partial > Partial
*Aux > Partial > Expand
*Aux > Partial > Boundary
Aux > Print out > CH
Aux > Print out > Trend
Aux > Print out > Periodic
Aux > Tag > CH
Aux > Tag > Tag
Aux > Message > Message number
Aux > Message > (Message)
Aux > Chart2
*Aux > Moving_AVE > CH
*Aux > Moving_AVE > number of samples Dot Model
*Aux > Filter > CH
*Aux > Filter > Response time
*Aux > Alarm delay time > CH
*Aux > Alarm delay time > Duration
Aux > Brightness > Display
Aux > Brightness > Light
IM 04P02B01-02E
The items with an asterisk are not displayed in the default condition. To display these
items, settings must be changed in Basic Setting mode.
Pen/Dot
-
-
-
-
-
-
Pen/Dot
-
-
-
-
-
Pen/Dot
-
-
-
-
-
-
-
-
-
Pen Model 82 types (pen model)
Dot Model
-
Dot Model
-
-
-
-
-
-
-
Dot Model
-
-
-
-
-
Pen Model 82 types (pen model)
Dot Model
Dot Model
Pen Model 01 to 24
Pen Model 2s/5s/10s
-
-
-
-
(Firmware version: 1.31)
Selectable Range or Selections
01 to 24
Volt/TC/RTD/1-5V/Scale
/Delta/DI/SQRT/Skip
20mV/60mV/200mV/2V/6V/20V/50V/1-5V
/R/S/B/K/E/J/T/N/W/L/U/WRe/Pt/JPt/Level/Cont
/(Slections for /N1 and /N3 options)
01 to 24
On/Off
±10 % of the span of the measurable range
Selectable Range or Selections
01 to 24
On/Off
Within the range
Within the range
(correction point + correction value for revise value)
Yes/No
Selectable Range or Selections
01 to 24
1/2/3/4
On/Off
H/L/h/l/R/r (*/T/t)
Depends on the alarm type.
On/Off
I01 to I06, I11 to I16, I21 to I26, I31 to I36
01 to 24
6 characters or less
1 to 1500 mm/h (dot model)
Date/Time
Auto/Fix
01 to 24
Within the recording span range (mm)
01 to 24
On/Off
1 to 99%
Within the recording span range
01 to 24
On/Off
On/Off
01 to 24
7 characters or less
1 to 5
16 characters or less
1 to 1500 mm/h (dot model)
01 to 24
Off, 2 to 16
01 to 24
0 to 3600s
1/2/3/4/5/6/7/8
1/2/3/4
Default Value
01
Volt
2V
01
Off
-
Default Value
01
Off
-
-
Yes
Default Value
01
1
Off
H
-
Off
I01
01
Blank
25 mm/h
25 mm/h
-
Auto
01
Left: 0, Right: 180
01
Off
50
-
01
On
On
01
01 to 24
1
Blank
25 mm/h
25 mm/h
01
Off
01
Off
01
10s
4
2
53