Checking the Contents of the Package

Unpack the box and check the contents before operating the
instrument. If some of the contents are not correct or missing or if
there is physical damage, contact the dealer from which you
purchased them.
µR20000 Recorder
A name plate is affixed to the case. Check that the model name
and suffix code given on the name plate on the rear panel match
those on your order.
NO. (Instrument Number)
When contacting the dealer from which you purchased the
instrument, please give them the instrument number.
MODEL and SUFFIX Code
Optional
Model Suffix
Code
Code
437101
437102
437103
437104
437106
437112
437118
437124
-2
/A1
/A2
/A3
/A4
/A5
/C3
/C7
/F1
/H2
/H3
/H5D
/H5F
/H5R
/H5J
/H5H
/M1
/N1
/N2
/N3
/P1
/R1
/CC1
/BT1
1 /A1, /A2, /A3, /A4, and /A5 cannot be specified
simultaneously. /A5 is valid on the dot models.
2 /A5 and /F1 cannot be specified simultaneously on the dot
models.
/A4 and /F1 cannot be specified simultaneously on the pen
models.
3 /C3 and /C7 cannot be specified simultaneously.
4 /H2 and /N2 cannot be specified simultaneously.
5 Valid only on the dot models.
6 14 types of input including Pt50 RTD, PR40-20, and
Platinel TC
7 /H5x and /P1 cannot be specified simultaneously.
IM 04P02B01-02E
MODEL
STYLE
SUFFIX
SUPPLY
FREQUENCY
MAC
NO.
Description
µR20000 1 pen recorder
µR20000 2 pen recorder
µR20000 3 pen recorder
µR20000 4 pen recorder
µR20000 6 dot recorder
µR20000 12 dot recorder
µR20000 18 dot recorder
µR20000 24 dot recorder
English/German/French & deg F/DST
1
Alarm output relay 2 points
1
Alarm output relay 4 points
1
Alarm output relay 6 points
Alarm output relay 12 points
Alarm output relay 24 points
3
RS-422A/485 interface
Ethernet (10BASE-T) interface
Fail/Chart end detection and output
4
Clamped input terminal
Non-glare door glass
Portable type Power cord UL, CSA st'd
Portable type Power cord VDE st'd
Portable type Power cord AS st'd
Portable type Power cord BS st'd
Portable type Power cord GB st'd
Mathematical function
Cu10, Cu25 RTD input
4,5
3 legs isolated RTD
6
Expansion inputs
7
24 VDC/AC power supply
Remote control 5 points
Calibration Correction
Header printout
Standard Accessories
Z-fold chart
paper
I
S A
K U
K O
T
A R
C H
Mounting
bracket
One of these power cord types is supplied
according to the instrument's suffix code
Part Number
A1006WD
A1009WD
A1024WD
A1023WD
A1064WD
1,2
1,2
3
Z-fold chart paper
2
Ribbon cassette
7
Disposable felt pen
7
7
7
Plotter pen
7
Mounting bracket (included with
models without /H5x)
Power cord (included with /H5x)
Manuals for the µR10000/µR20000
(CD-ROM)
µR20000 Recorder Operation
Guide IM 04P02B01-02E
Software (Sold Separately, see page 7)
Configuration software
* You can use the Configuration Software if you install the interface
unit to a recorder does not include the communication function.
Plotter pen
Disposable
felt pen
t
h a r
g C
d in
c o r
R e
Manuals for the
µR10000/µR20000
(CD-ROM)
/H5F
/H5D
/H5J
Note
Provided when optional code /H5D is specified.
Maximum rated power voltage: 125V
Provided when optional code /H5F is specified.
Maximum rated power voltage: 250V
Provided when optional code /H5R is specified.
Maximum rated power voltage: 250V
Provided when optional code /H5J is specified.
Maximum rated power voltage: 250V
Provided when optional code /H5H is specified.
Maximum rated power voltage: 250V
Item
1
-Pen
1
-
Red
1
Green
-
Blue
-
Violet
-
Purple
1
2
1
1
1
Item
Model
RXA10-01
RXA10-02
Ribbon
cassette
µR20000 Recorder
Operation Guide
IM 04P02B01-02E
/H5R
/H5H
2
3
4
Dot
-Pen
-Pen
-Pen
1
1
1
1
-
-
-
1
1
1
1
-
1
1
1
-
-
1
1
-
-
-
1
-
1
1
1
-
2
2
2
2
1
1
1
1
1
1
1
1
1
1
1
1
Note
With interface unit*
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

437101437102437103437104437106437112 ... Show all

Table of Contents