5.5.2.1

TECHNICAL DATA

Description
Pump ratio
Volume fl ow per double stroke (
Maximum operating overpressure
Maximum possible strokes in operation
Maximum recommended strokes per minute in
continuous operation
Minimum / maximum air inlet pressure
Compressed air quality: free from oil and water
Ø air inlet connection (inside thread)
Minimum Ø of the compressed air supply line
Air consumption at 0.6 MPa; 6 bar; 87 psi per double
stroke
Air motor piston diameter
Air motor piston stroke
Sound pressure level at maximum permissible air
pressure*
Sound pressure level at 0.6 MPa; 6 bar; 87 psi air
pressure*
Sound pressure level at 0.4 MPa; 4 bar; 58 psi air
pressure*
Product inlet (outside thread)
Product outlet (inside thread)
Weight
Product pH value
Maximum product pressure at pump inlet
Product temperature
Ambient temperature
Relative humidity
Allowable inclination for operation
A-rated sound pressure level measured at 1 m distance, LpA1m, according to DIN EN 14462: 2005.
ORDER NUMBER DOC2333553
)
Construction and assembly
Suspension
Units
cm3/cc
MPa
bar
psi
/min.
/min.
MPa
bar
psi
Quality standard 7.5.4 according to ISO 8573.1: 2010
7: Particle concentration 5 – 10 mg/m³
5: Humidity: Pressure dew point ≤ +7 °C
4: Oil content ≤ 5 mg/m3
mm
inch
mm
inch
nl
scf
mm
inch
mm
inch
dB(A)
dB(A)
dB(A)
mm
inch
kg; lb
pH
MPa
bar
psi
; °F
+5 ... +80; +41 ... +176
; °F
+5 ... +50; +41 ... +122
; °F
%
10–95 (without condensation)
EvoMotion 20-30
20:1
30
13.5
135
1958
60
40
0.2-0.8
2-8
28-116
8.0
0.31
9.0
0.35
3.9
0.14
80
3.15
60
2.4
72
69
65
M36x2
NPS 1/4"
11.0; 24.7
3.5 – 9
2
20
90
-20...+60 ; -4...+140
± 10
22