7.6
BASIC FLUSHING
Before each basic fl ushing, the nozzle must be removed from the gun. The data in the gun's operating manual
are to be observed.
With AirCoat systems, carry out the basic fl ushing of the system without atomizing air (8).
1. Visual check: personal safety equipment, grounding and all devices ready to use.
2. Place empty tank (5) under return tube (4).
3. Place suction hose (7) in the tank with fl ushing agent (6).
4. Open return valve (3).
5. Slowly open the ball valve (2).
6. Adjust the air pressure on the pressure regulator (1) so that the pump runs smoothly.
7. Flush the system until clean fl ushing agent fl ows into the tank (5).
8. Close ball valve (2).
9. Close return valve (3).
10. Point the gun (9), without nozzle, into tank (5) and open it.
11. Slowly open the ball valve (2).
12. Rinse until clean fl ushing agent fl ows from the gun.
13. Close ball valve (2).
14. Relieve the system pressure, either by opening the return valve (3) or via the trigger on the gun (9).
15. When there is no pressure remaining in the system, close the gun (9) or the return valve (3).
16. Secure the gun.
17. Dispose of the contents of the tank (5) according to the local regulations.
closed
open
C_00157
7
6
ORDER NUMBER DOC2333553
1
8
2
3
4
9
5
B_04111
39