Maintenance; Maintenance Staff; Safety Instructions - WAGNER EvoMotion 20-30 Operating Manual

Piston pumps flow rate 30 cm3
Hide thumbs Also See for EvoMotion 20-30:
Table of Contents

Advertisement

VERSION 11/2015
OPERATING MANUAL
8.2

MAINTENANCE

8.2.1

MAINTENANCE STAFF

Maintenance work should be undertaken regularly and carefully by qualifi ed and trained
staff . They should be informed of specifi c hazards during their training.
The following hazards may arise during maintenance work:
- Health hazard from inhaling solvent vapors
- Use of unsuitable tools and aids
An authorized person must ensure that the device is checked for being in a reliable state
after maintenance work is completed.
8.2.2

SAFETY INSTRUCTIONS

Observe the safety instructions in Chapter 4 and Chapter 8.1.2.
Prior to maintenance
It should be ensured that the device is in the following state before carrying out any work
on it:
- Release pressure from the pump, high-pressure hose and gun.
- The gun should be secured with the safety clip.
- The air supply should be interrupted.
After maintenance
- Commissioning in accordance with Chapter 6.6.
According DGUV regulation 100-500:
- The liquid ejection devices should be checked by an expert (e.g., WAGNER service
technician) for their safe working conditions as required and at least every
12 months.
- For shut down devices, the examination can be suspended until the next start-up.
Incorrect maintenance/repair!
Danger to life and equipment damage.
ORDER NUMBER DOC2333553
DANGER
Repair or replacement of devices or parts of devices are only
allowed to be performed outside the hazard area by qualifi ed
personnel.
44

Advertisement

Table of Contents
loading

Table of Contents