Select Apply.
The FortiGate unit shuts down and all traffic flow stops.
To reset the FortiGate unit to factory defaults
Use the following procedure to reset system settings to the values set at the factory.
This procedure does not change the firmware version or the antivirus or attack
definitions.
Caution: This procedure deletes all changes that you have made to the FortiGate configuration
and reverts the system to its original configuration, including resetting interface addresses.
1
Go to System > Maintenance > Shutdown.
2
Select Reset to factory default.
3
Select Apply.
The FortiGate unit restarts with the configuration that it had when it was first powered
on.
4
Reconnect to the web-based manager and review the system configuration to confirm
that it has been reset to the default settings.