Set Weight - Fortinet FortiGate FortiGate-5001 Administration Manual

Fortigate 5000 series
Hide thumbs Also See for FortiGate FortiGate-5001:
Table of Contents

Advertisement

System Config
FortiGate-5000 series Administration Guide
2
Power on all of the cluster units.
As the cluster units start, they negotiate to choose the primary unit and the
subordinate units. This negotiation occurs with no user intervention and normally just
takes a few seconds.
You can now configure the cluster as if it is a single FortiGate unit.
To add a new unit to a functioning cluster
1
Configure the new cluster unit for HA operation with the same HA configuration as the
other units in the cluster.
2
If the cluster is running in Transparent mode, change the operating mode of the new
cluster unit to Transparent mode.
3
Connect the new cluster unit to the cluster.
4
Power on the new cluster unit.
When the unit starts it negotiates to join the cluster. After it joins the cluster, the cluster
synchronizes the new unit configuration with the configuration of the primary unit.
To configure weighted-round-robin weights
By default, in active-active HA mode the weighted round-robin schedule assigns the
same weight to each cluster unit. From the CLI you can use the following command to
configure a weight value for each cluster unit.
config system ha
set weight <priority-id_integer> <weight_integer>
end
The weight value sets the maximum number of connections that are sent to a cluster
unit before a connection can be sent to the next cluster unit. You can set weight
values to control the number of connections processed by each cluster unit. For
example, you might want to reduce the number of connections processed by the
primary cluster unit by increasing the weight assigned to the subordinate units.
Weight values are entered as two values; the priority order of the unit in the cluster (in
the range 0 to 31) followed by its weight (also in the range 0 to 31). For example, if you
have a cluster of three units, you can enter the following commands to configure the
weight values for each unit:
Table 6: Example weights for three cluster units
Cluster unit priority
0
1
2
config system ha

set weight 0 1

set weight 1 3
set weight 2 3
end
Weight
1
3
3