Water Connection Requirements

To prevent personal injury, avoid contact with inlet
water temperatures higher than 125° Fahrenheit [51°
Celsius] and hot surfaces.
Hot water is used to flush the supply dispenser. Do
not open the supply dispenser lid while the machine
is running. The discharge or splashing of hazardous
liquid can cause serious scalding and burning.
Models manufactured through April, 2017
1
NOTE: North American Models: Water inlet hose with
notches should be connected to the water supply
faucet, while the side of the water inlet hose without
notches should be connected to the water inlet
valves.
1. Water inlet valve connection (hose connection without
notch)
2. Water supply faucet connection (hose connection with
notch)
Figure 16
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
WARNING
WARNING
2
CHM2503N_SVG
Models manufactured starting May, 2017
1
W748
NOTE: North American Models: Install threaded re-
duction pieces together with sealant on all inlet
valves. The filling hose end piece with an internal fil-
ter must be connected to the water inlet tap. The
second end of the hose must be connected to a re-
duction piece.
1. Hose
C377
2. Reduction
3. Seal
4. Valve
NOTE: Models outside of North America: For 7.5 kg / 20
lb. / 75 L, 10.5 kg/ 25 lb. / 105 L, 13.5 kg / 30 lb. / 135 L ,
18 kg/ 40 lb. / 180 L and 24 kg / 55 lb. / 240 LModels, to
connect cold water, use a hose with plastic elbow. To
connect hot water, use a hose with metal elbow.
NOTE: For HX65, HX80, HX105, HX135, HX180, and
HX240 Models, to connect cold water, use a hose with
plastic elbow. To connect hot water, use a hose with
metal elbow.
Do not re-use water hoses; only use new water hoses.
The appliance has been designed with a built-in "AB" airgap sys-
tem according to EN1717. Nevertheless, when potable water will
be connected to the appliance, a WRAS approved double check
valve or some other no less effective device providing backflow
prevention protection to at least fluid category three shall be fit-
ted at the point of connections between the water supply and the
appliance.
All intake connections to the machine are to be fitted with man-
ual shut-off valves and filters, to facilitate installation and servic-
ing.
All water connectors present on the machine must be connected
or the wash program will not function correctly. Refer to Table 12
for possible connection options, which will depend on the water
types to be connected to the machine, which can be found by