Installation
Electrical Connection of External
Liquid Soap Supply System
The power supply of the external liquid soap supply system has
to be connected to an external electrical source. Only authorized
workers with valid qualifications must execute the electrical con-
nection on the machine according to valid local standards. The
correction connection can be found on the wiring diagram inclu-
ded with the machine. Do not connect the liquid soap pump sys-
tem in the washer.
The electric connection for supply control signals is available on
the rear panel. Refer to #unique_56/
unique_56_Connect_42_fig_z4f_21p_dm. At the terminal box,
there is a label for electric connection. Detail on connection of
signals can also be found on the electric scheme of the machine.
Figure 37
Signals for supply pump control are 24 VAC. Maximum current
for control circuits of pump must be limited to 100mA. Lead the
cable for connection of pump control signals through the plastic
cable bushing. After connection of conductors to the respective
positions of the connector "P", fix up the cable by tightening the
cable bushing against disconnections and close the box with the
cover. For details about liquid soap supply sytem programming,
refer to Programming Manual.
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT

External Wait Control

This function can be activated by an external contact which is
connected between the pins
#concept-4941/fig-1608226298044 . Such connection is possible
only with machines which had been ordered with the "Heating
Delay / Waiting for Detergent" option.
Valve Panel-Rear View
1. External Supply Hose Connections
2. Cable Bushing
3. Control Signals Terminal Box

Chemical Injection Supply System

Wear eye and hand protection when handling chemi-
CFD3113N
cals; always avoid direct contact with raw chemicals.
Read the manufacturer's directions for accidental
contact before handling chemicals. Ensure an eye-
rinse facility and an emergency shower are within
easy reach. Check at regular intervals for chemical
leaks.
Undiluted chemical dripping can damage the washerextractor.
Therefore, all chemical supply dispenser pumps should be moun-
ted below the washerextractor's injection point. All dispenser
tubing should also run below the injection point. Loops do not
prevent drips if these instructions are not followed. Failure to fol-
low these instructions could damage the machine and void the
68
and . Refer to Figure 38 and
Figure 38
WARNING
Part No. D1599ENR14
C365

Hide quick links: