Drain Connections
Specification
Drain connection number
Drain connection size, in. [mm]
Average flow rate of draining gal/min. [l/
min.]
Drain pump with hose - internal diameter
of hose, in [mm]
Flow rate of drain pump, gal/min. [l/
min.]
The main drain channel-pipe must have the capacity to be able to
handle the total output of all connected machines. In a drainpipe,
a vent must be provided every 65.62 ft. [20 m] to assure the drain
pipe will work. If the main drain pipe cannot be sufficiently ven-
ted, install a vent per machine. Every time a machine is coupled
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
Model
7.5 kg - 28 kg /
20 lb.- 70 lb./
75 L- 280 L
35 kg - 52 kg /
80 lb.- 120 lb. /
332 L- 520 L
All
7.5 kg - 28 kg /
20 lb.- 70 lb./
75 L- 280 L
35 kg - 52 kg /
80 lb.- 120 lb. /
332 L- 520 L
7.5 kg /
20 lb. /
75 L
7.5 kg /
20 lb. /
75 L
Table 10
on the drainpipe, the diameter of the tube or the width of the
waste channel must increase. Refer to Figure 14 .
The diameters of drain pipe for machines with two drain valves
must have dimensions suitable for double the value of water flow.
38
Requirement
1
2
3 [76]
55.48 [210]
110 [420]
0.75 [19]
9.51 [36]