Maintenance
NOTE: Unload the machine promptly after each
completed cycle to prevent moisture buildup. Leave
loading door open at the end of each completed cy-
cle to allow moisture to evaporate.
5. Leave the loading door open at the end of each day to allow
moisture to evaporate.
6. Shut off water supply.

Quarterly

NOTE: Disconnect power to the machine at its source
before performing the quarterly maintenance proce-
dures.
1. Check the bearing house for leakage.
2. Verify that the drain valve is operating and that the drain sys-
tem is free from obstruction. If water does not leak out during
the first wash segment, the drain valve is closed and function-
ing properly.
3. Visually check all hoses and connections inside machine for
leaks.
4. Make sure that control components are protected against
moisture and dust during the clean up. Wipe and clean the
machine inside.
5. For models with electric heat, check the tightening of the con-
tacts of heating elements terminals and other power terminals
(main switch, fuse disconnectors, contactors).
6. In order to increase the service life of the door gasket, apply a
glycerine-based impregnating agent.
7. Open the door approximately 15-20°.
a. Try to move the door up and down. If the door is able to
be moved, add a .5mm thick washer to the fixed lower
hinge pin. The washer was included when the machine
was delivered, but can be ordered from Alliance Laundry
Systems under part number 571642.
b. Try to turn the door in a clockwise or counterclockwise
rotation. If the door can me moved clockwise or counter-
clockwise, replace the door hinges.
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT

Every 6 Months

NOTE: Disconnect power to the machine at its source
before performing maintenance procedures.
1. Clean the water valve filters.
Before you start cleaning the water filters, make
sure all water inlets to machine are closed.
a. Turn off the water supply.
b. Unscrew the hoses at the back of machine.
c. Take out filter at center with pointed pliers.
d. Clean the filter and re-insert.
e. When reattaching the hoses, make sure the seals are seated
correctly.
f. Check water inlets for leaks.
g. Tighten the connections or replace the seals of inlet hose if
necessary.
2. If machine is fitted with a drain pump, make sure the pump
provides normal flow rate during draining. The drain pump
can be cleaned when it becomes clogged with foreign objects.
a. Drain all water from machine.
b. Disconnect machine from power supply.
c. Remove the front panel of cabinet by unlocking bolts. Re-
fer to Figure 42 .
1. Bolts
2. Pump lid
d. Slightly turn the pump lid until water starts flowing out,
making sure to catch the water.
e. Unscrew the lid and remove any foreign objects.
f. Reattach pump lid and front panel of cabinet.
3. Remove dust or dirt and verify functionality of the following:
a. Inverter cooling fin