Halt; Counter - Mitsubishi Electric PLK-G-CU-20 Technical Manual

Industrial sewing machine
Table of Contents

Advertisement

8.Halt

Function
STF
Stop position setting when
halt switch is pressed while
non stitch feed operation
STN
Needle position when halt
switch is turned on.
STS
The state of each output
when the HALT switch is
turned on
ST2
HALT switch two-press
operation (stop at down
position)
STP
Operation of power supply
after HALT switch is turned
on and off. <TURN OFF
THE POWER>
STD
Clamp condition during
halt state by the STOP
code
STL
Prevention of two drops at
the same point after HALT

9.Counter

Function
CUP
Sets function of UP
counter
CDN
Sets function of DOWN
counter
CNU
Setting number of stitches
of each 1 count for UP
counter
CND
Setting number of stitches
of each 1 count for DOWN
counter
Unit
Setting range
Stop position when halt switch is pressed while non stitch feed operation can be set
-
CP
ST
Sets needle positioning when the halt switch is turned on.
-
DN
UP
Selects the state of each output when the HALT switch is turned on.
-
AL
FU
OF
The operation for when the HALT switch is pressed twice at the needle down position can be
selected.
-
UT
UP
ST
Sets the operation after HALT switch is turned on.
Please turn off the power after the setting change and restart again.
-
--
PD
Sets the clamp condition during halt state by the STOP code
-
FU
FD
After needle down position stop, restart operation can be selected.
-
OF
ON
Unit
Setting range
Sets function of UP counter
-
--
ED
ST
CY
Sets function of DOWN counter
-
--
ED
ST
CY
5 ~ 1000
stitches
5 ~ 1000
stitches
When the HALT switch is turned ON, non-stitching feed will be
executed until the breakpoint (the position where non-stitching
feed direction changes).
When the HALT switch is turned ON, the machine will stop at that
position.
When the HALT switch is on, the needle will stop at the DOWN
position.
When the HALT switch is on, the needle will stop at the UP
position.
All outputs will be held (ON is maintained). (exclude wiper,
trimmer, thread release)
Keep the output state of the clamp relation.(keep output
excluding general purpose, wiper, trimmer and tension release)
Release output for the clamp relation, general purpose, wiper,
trimmer, tension release.
When the HALT switch is turned on again, the needle will stop at
the up position after thread trimming.
When the HALT switch is turned on again, the needle will stop at
the up position without thread trimming. (when set (STN.)=[DN])
The needle will stay at the down position even if the HALT switch
is turned ON again.
Restarting is possible after the sewing machine is stopped by the
foot switch.
Same behavior as emergency stop switch. please turn off the
power and restart again.
Clamp goes up after machine is stop
Keeps clamp condition after machine is stop
After needle down position stop, machine restarts from the stop
position ( needle goes down at the same position twice)
After needle down position stop, machine restarts from next stitch
point ( needle does not go down at the stop position)
Up counter is not executed
Up counter decreases every 1 sewing pattern is executed
Up counter decreases every N stitches (N is set by [CND] setting)
Do not use
Down counter is not executed
Down counter increases every 1 sewing pattern is executed
Down counter increases every N stitches (N is set by [CNU]
setting)
Do not use
Setting of the number of stitches when "ST" of the CUP setting is
selected
Setting of the number of stitches when "ST" of the CDN setting
is selected
[16] - 7
Specification
Specification

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents