Model And Support Materials; Uv Lamps - Stratasys Connex500/350 User Manual

Table of Contents

Advertisement

Model and
Support
Materials

UV Lamps

DOC-13025 Rev. A
Model and support materials are made of chemical substances. Although 
precautions must be taken when handling these materials directly, all 
model and support materials used by the Connex system are handled in 
sealed cartridges. Normally, operators of the printer should never be 
directly exposed to hazardous materials. In the unlikely event of a leak or 
spill, follow the instructions that are included with the printing‐material 
cartridge used.
Store model and support materials indoors, in a dry area with adequate 
ventilation, between 16‐27 degrees Celsius (60‐81 degrees Fahrenheit). 
Never expose them to flames, heat, sparks, or direct sunlight.
Keep model and support materials away from areas where food and 
drink are stored, prepared and consumed.
Uncured printing material is considered a hazardous substance, 
requiring certain precautions when directly handling it. To prevent skin 
irritation, wear neoprene or nitrile gloves. If there is any chance that 
model and support materials might splash into the eyes, wear safety 
goggles. Prolonged direct contact with printing materials can cause an 
allergic reaction.
When handling UV‐cured models that may not be completely cured on 
the surface, common latex gloves are adequate. 
To prevent respiratory irritation, ventilate areas where model and 
support materials are used. If the printer is not equipped with an 
exhaust duct, the room ventilation system should replace the air at least 
20 times per hour. 
Clean up model‐material and support‐material spills with disposable 
towels or other absorbent, non‐reusable material, such as sawdust or 
activated charcoal. Rinse the spill area with denatured or isopropyl 
alcohol (IPA), followed by soap and water. Dispose of the absorbent 
material in accordance with local regulations.
Do not wash contaminated clothing at home; clothing should be 
professionally laundered.
Dispose of contaminated shoes, belts and other leather items in 
accordance with any applicable regulations. Absorbed printing 
material may re‐expose the user when these items are worn.
UV lamps used by the printer to cure printing materials contain a small 
amount of mercury. In the unlikely event of lamp breakage, avoid inhaling 
mercury vapor, and ventilate the room. If the lamp ruptures (breaks) 
during operation, leave the room and ventilate it thoroughly (for about 30 
minutes). 
Use protective gloves to prevent contact with mercury and other lamp 
components. Carefully remove spilled mercury with a method that 
prevents the generation of mercury vapor, such as a syringe, packing tape 
or paper. 
Place the broken lamp, mercury and contaminated materials in an air‐tight, 
non‐metallic container. Dispose of the container in accordance with 
applicable regulations.
Connex500/350 User Guide