Testing And Calibrating The Uv Lamps - Stratasys Connex500/350 User Manual

Table of Contents

Advertisement

Operating & Maintaining the Connex500/350 3D Printer
Testing and
Calibrating the
UV Lamps
6–50
The effective UV radiation from the lamps used for curing models can 
change over time. To ensure optimum curing of models during printing, a 
pop‐up message reminds you to test the lamps and calibrate their effective 
UV radiation after every 300 hours of printing. You do this by running the 
UV Calibration Wizard.
To measure the UV radiation, you need:
TOL‐03003‐S (UV sensor and cable, supplied with the printer)
or—
a stand‐alone UV radiation meter, approved for use with the printer
The wizard compares the measured radiation to the recommended 
radiation level for each of the lamps, at each printing mode—High Speed,  
High Quality and Digital Material.
When calibrating the lamps, the wizard attempts to adjust the radiation 
level, if necessary.
If the reading is within the acceptable range, the wizard continues to 
the next phase. 
If further adjustment is necessary, the current phase is repeated. 
If the UV radiation is too low to be properly adjusted, the wizard 
continues to the next phase, but the final wizard screen indicates that 
the lamp's radiation for the printing mode is unacceptable.
Before testing and calibrating the UV lamps:
Make sure the glass lens on each of the UV lamps is clean. For easy
access, run the Head Cleaning Wizard, and use the special cleaning pad
supplied.
Make sure that the glass over the UV radiation sensor is clean.
To test and calibrate UV lamp radiation:
1. Start the UV Calibration Wizard from the Options menu (see figure 6‐27 
on page 6‐25).
2. In the following screen, select 
radiation level to the acceptable range. 
Figure 6-73: UV Test/Calibration selection
Calibrate UV Intensity
to adjust the lamp's 
DOC-13025 Rev. A