3. In the following screen, select the UV sensor and measuring device to
be used.
Figure 6-74: UV device selection
UV Measuring Device
When you use UV sensor TOL-03003-S, you connect it to the printer. The
wizard automatically measures and calibrates the UV radiation.
If you use a stand-alone UV radiation meter, you need to manually enter the
readings from the meter in the wizard screens.
4. Make sure that the build tray is clear (empty), confirm this in the
wizard screen and click
Figure 6-75: Printer preparation
When using UV sensor TOL‐03003‐S, continue with "UV sensor
connected to printer," below.
When using a stand‐alone radiation meter, continue with "External UV
meter" on page 54.
Connex500/350 User Guide
.
Next
6–51