Busy Out is used to block any trunk for both incoming and outgoing calls. (This feature may be used to block
[BOut]
faulty trunks until the CO service is restored.) When ASSIGN appears in the display the trunk line is blocked.
DEASSIGN means the trunk line is in use by the system.
♦
Drop No Dial is used to program an outgoing trunk to be dropped when a caller does not dial the first digit
[Drop]
within a system-wide time limit. The trunk is then made available to other users.
♦
Hot Trunk Immediate is used to program an outgoing trunk so that the trunk automatically and immediately
[HotI]
connects to the system.
♦
Hot Trunk Delay is used to program an outgoing trunk to automatically connect to the system, after first
[HotD]
digit time-out, when no dialing has taken place.
♦
Incoming Only is used to reserve any trunk for incoming calls only, thereby preventing outgoing calls on
[IncO]
that trunk.
♦
Outgoing Only is used to reserve any trunk for outgoing calls only. All incoming calls on that trunk will
[OutO]
continue ringing with no answer and will not be transferred to any destination.
Reserved To is used to reserve any trunk and trunk group to a specific station or boss group. The reservation
[Rsvd]
will prevent any other stations or boss group stations from making outgoing calls on these trunks.
Attendant Features
Trunk Setup Features