Air-Cooled Machines; Water Connections; Electrical Connections - Taylor 632 Operator's Manual

Combo freezer
Table of Contents

Advertisement

TO THE INSTALLER
CAUTION! This machine must be installed on
a level surface to avoid the hazard of tipping. Extreme
care should be taken when moving this machine for any
reason. Two or more persons are required to safely move
1
this machine. Failure to comply may result in personal
injury or machine damage.
Uncrate the machine and inspect it for damage. Report
any damage to your Taylor distributor.
This piece of equipment is made in the USA and has
USA sizes of hardware. All metric conversions are
approximate and vary in size.

Air-Cooled Machines

Do not obstruct air intake and discharge openings:
Air-cooled machines require a minimum of 3 in. (76 mm)
of clearance around all sides of the freezer to allow for
adequate air flow across the condensers. A deflector is
provided to prevent recirculation of warm air. Failure to
allow adequate clearance can reduce the refrigeration
capacity of the freezer and possibly cause permanent
damage to the compressor.

Water Connections

Water-Cooled Machines Only: An adequate cold water
supply must be provided with a hand shut-off valve. On
the underside rear of the base pan, two 1/2 in. Iron Pipe
Size (IPS) water connections for inlet and outlet have
been provided for easy hook-up. Connect the machine
using 1/2 in. inside diameter water lines. Flexible lines
are recommended, if local codes permit. Depending on
local water conditions, it may be advisable to install a
water strainer to prevent foreign substances from
clogging the automatic water valve. There will be only
one water in and one water out connection for both
single-head and double-head machines. Do not install a
hand shut-off valve on the water out line. Water should
always flow in this order: first, through the automatic
water valve; second, through the condenser; and third,
through the outlet fitting to an open trap drain.
1-2
All manuals and user guides at all-guides.com
required on the incoming water connection side. Please
see the applicable national, state, and local codes for
determining the proper configuration.

Electrical Connections

machine is intended to be installed in accordance with
the National Electrical Code (NEC), ANSI/NFPA 701987.
The purpose of the NEC code is the practical
safeguarding of persons and property from hazards
arising from the use of electricity. This code contains
provisions considered necessary for safety.
In all other areas of the world, machine should be
installed in accordance with the existing local codes.
Please contact your local authorities.
Each machine requires one power supply for each data
label on the machine. Check the data label(s) on the
machine for branch circuit overcurrent protection or fuse,
circuit ampacity and other electrical specifications.
Refer to the wiring diagram provided inside the electrical
box for proper power connections.
Each machine requires one power supply for each data
label on the machine. Check the data label(s) on the
freezer for branch circuit over current protection or fuse,
circuit ampacity and other electrical specifications. Refer
to the wiring diagram provided inside of the electrical box,
for proper power connections.
grounded! Failure to do so can result in severe personal
injury from electrical shock!
Model 632
IMPORTANT! A backflow prevention device is
IMPORTANT! In the United States, this
FOLLOW YOUR LOCAL ELECTRICAL CODES.
WARNING! This machine must be properly
To the Installer

Advertisement

Table of Contents
loading

Table of Contents