Air-Cooled Machines; Electrical Connections - Taylor 432 Operator's Manual

Frozen beverage unit with raised drip tray
Hide thumbs Also See for 432:
Table of Contents

Advertisement

TO THE INSTALLER

Air-Cooled Machines

Do not obstruct air intake and discharge openings:
A minimum of 6 in. (152 mm) on both sides and 0 in. on
the back is required. Failure to follow this instruction may
cause poor freezer performance and damage to the
machine.
1

Electrical Connections

This machine must be plugged into a properly grounded
receptacle. The cord and plug must be sized for 20A
usage. The voltage specifications are 208-230/60/1.
Follow specifications listed on your data plate.
FOLLOW YOUR LOCAL ELECTRICAL CODES.
IMPORTANT! In the United States, this
machine is intended to be installed in accordance with
the National Electrical Code (NEC), ANSI/NFPA 701987.
The purpose of the NEC code is the practical
safeguarding of persons and property from hazards
arising from the use of electricity. This code contains
provisions considered necessary for safety.
In all other areas of the world, the machine should be
installed in accordance with the existing local codes.
Please contact your local authorities if you have any
questions.
Each machine requires one power supply for each data
label on the machine. Check the data label(s) on the
machine for branch circuit overcurrent protection or fuse,
circuit ampacity, and other electrical specifications.
See the wiring diagram provided inside the electrical box
for proper power connections.
WARNING! This machine must be properly
grounded. Failure to do so can result in severe personal
injury from electrical shock.
1-2
IMPORTANT! An equipotential grounding lug is
provided with this machine. Some countries require the
grounding lug be properly attached to the rear of the
frame by the authorized installer. The installation location
is marked by the equipotential bonding symbol (5021 of
IEC 60417-1) on both the removable panel and the
machine's frame.
IMPORTANT!
Stationary machines which are not equipped
with a power cord and a plug or another device
to disconnect the machine from the power
source must have an all-pole disconnecting
device with a contact gap of at least 0.125 in.
(3 mm) installed in the external installation.
Machines that are permanently connected to
fixed wiring and for which leakage currents may
exceed 10 mA, particularly when disconnected
or not used for long periods, or during initial
installation, shall have protective devices, to
protect against the leakage of current such as a
GFI, installed by the authorized personnel to the
local codes.
Supply cords used with this machine shall be
oil-resistant, sheathed flexible cable not lighter
than ordinary polychloroprene or other
equivalent synthetic elastomer-sheathed cord
(code designation 60245 IEC 57) installed with
the proper cord anchorage to relieve conductors
from strain, including twisting, at the terminals
and protect the insulation of the conductors from
abrasion.
If the supply cord is damaged, it must be
replaced by a Taylor service technician in order
to avoid a hazard.
Secure the supply cord ground lead to the
machine in a location where if the cord is pulled,
the main power leads will become taut before
the ground lead can break loose.
Model 432
To the Installer

Hide quick links:

Advertisement

Table of Contents
loading