Install the alarm plate (See Figure 1)
1. Strip back the ends of 50 ft. cable conductors ¼ in. Loosen the two
screws on the back of the alarm plate. Wrap each wire around
each screw. Tight the screws to secure the wires.
2. Mount the alarm plate no less than five (5) feet
from the pool/spa in a standard outlet box
(purchased separately), type: 22.5 cubic inches
(minimum) - Suitable for wet locations with UL/
CSA approval listings. Check the inside of outlet
box for specification label. The outlet box should
accept a minimum of one 3/4" steel conduit.
3. Secure the alarm plate with the two Phillips head
screws provided.
4. Route the two conductor cable from the alarm up
through the Power Center grommet opening
located on the left side, and up through the low voltage raceway to
the SVRS circuit board.
5. Connect the cable plug to the PUMP output connector on the
SVRS Alarm circuit board.
GAS
HEATER
RESET
CR2032
SVRS Alarm
+3V
circuit board
COM PORT
J11
Figure 1
Note:
(*) Device connected to PUMP and AUX 1 are ON when alarm is ON.
(**) Device connected to "AUX 2" is OFF when alarm is ON.
(***) Device connected to "AUX 3" is always ON. This output connector is used
for the ESO3 connection. When alarm is activated, press ESO3 button to shut
power OFF to the pump. Pull out the ESO3 button to re-enable pump
power.
"Pump" connects
to Alarm
LIGHT etc. (*)
CLNR
SPA, BLOWER etc. (**)
ESO3 (***)
SVRS Audible Alarm Installation and User's Guide