Installing The Svrs Audible Alarm System; Svrs Connection And Alarm Modes - Pentair SunTouch Installation And User Manual

Safety vacuum release system (svrs) audible alarm for use with intelliflo vs+ svrs and intellipro vs+ svrs pumps
Table of Contents

Advertisement

18

Installing the SVRS Audible Alarm System

The following illustration shows the IntelliFlo VS+ SVRS pump connected to the
SVRS Alarm circuit board using the pump's RS-485 two-wire communication
cable (provide with pump) and the SVRS audible alarm connected to the SVRS
circuit board using a 50 ft. two-conductor cable (provided in kit). The Emergency
Shut-Off switch (ESO3) accessory (not shown - see page 21), for commercial
spa pump applications, can also be connected to the SVRS Alarm power center
(for more information, see page 21).
SVRS
SVRS Audible
Audible
Alarm
Alarm
IntelliFlo VS+ SVRS
SVRS Alarm Connections and Alarm Modes
The SVRS Alarm system alarm modes are:
SVRS Alarm circuit board input connections "Pump" and "Aux 1"
are only ON when the alarm is ON.
SVRS Alarm circuit board input connection "Aux 2" is only OFF
when the alarm is ON.
SVRS Alarm circuit board input connection "Aux 3" is always ON.
This connection is for the ESO3 option. Pressing the ESO3 red
button will shut power off to the pump.
For more information about auxiliary input connection, see page 19.
Connecting the SVRS Alarm Plate
The SVRS Alarm plate is connected to the SVRS Alarm circuit board using the
provided 50 ft. two-conductor cable. Mount the alarm plate in a standard outlet
box near the pool and spa area (within listening distance of the alarm).
SVRS Audible Alarm Installation and User's Guide
SVRS Alarm
Power Center
5
Low Voltage
High Voltage
SUB PANEL
CIRCUIT BREAKERS
IntelliFlo VS+ SVRS pump

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents