Required Action for SVRS blockage Event

(Manual Mode, SVRS Auto Restart "Enabled/Disabled")
System Normal
1520 rpm 340 Watt
Note: The pump will not restart automatically in "Soft Prime" mode.
Pump Stopped and SVRS Audible Alarm ON due to blockage:
Check for blockage in pool/spa.
Remove blockage.
Press Reset/Restart button once (alarm OFF)
Soft Restart in
5 Seconds
Check for Drain
!!! Blockage !!!
To restart pump, enter SERVICE MODE:
button then the Right arrow button to enter "Service" mode.
Press one of the SPEED buttons on pump.
Press Start/Stop button on pump to restart.
Exit SERVICE MODE:
alarm. To exit Service mode, press the Menu button until the
main screen displays.
System Normal
1520 rpm 340 Watt
Pump in "Manual" mode and SVRS "Auto Restart"
feature "Enabled or Disabled."
The display toggles between these two alert
messages. After a five (5) second countdown
the pump will stop. Display shows "Pump Not
Running."
Press the Menu button on the SVRS
The system returns to normal
operation (if blockage is removed)
SVRS Audible Alarm Installation and User's Guide