Enable Or Disable The "Svrs Auto Restart" Setting - Pentair SunTouch Installation And User Manual

Safety vacuum release system (svrs) audible alarm for use with intelliflo vs+ svrs and intellipro vs+ svrs pumps
Table of Contents

Advertisement

10

Enable or Disable the "SVRS Auto Restart" Setting

To enable or disable the SVRS Auto Restart setting:
1. Check that the green power LED is on.
2. Press the Menu button. "Settings" is displayed.
3. Press the Select button. "Pump Address" is displayed.
4. Use the Up or Down arrow button to scroll to "SVRS".
5. Press the Select button. "Enabled Auto Restart" is displayed.
To Disable the setting, press the Select button to highlight
"Enabled" and press the Down arrow button to change the
setting to "Disabled," then press the Enter, and Escape button.
6. Press the Down arrow button to display "SVRS Restart Time."
This is the duration of time that the pump will restart after a
blockage if no buttons are pressed on the SVRS alarm control
panel and the pump's "SVRS Auto Restart" feature is enabled.
7. Press the Select button to change the setting. The cursor will
appear in the time column.
8. Press Up or Down arrow button to change the auto restart time
from 30 seconds to 5 minutes.
9. Press the Enter button to save the setting. To cancel any changes,
press the Escape button to exit edit mode without saving.
10. Press the Escape button to exit.
IntelliFlo Pump Control Panel Buttons and Display Message
While the SVRS Audible Alarm is active and communicating with the IntelliFlo
VS+ SVRS or IntelliPro VS+ SVRS pump, the pump control panel displays
"Display Not Active" and the pump control buttons are disabled.
SVRS Audible Alarm Installation and User's Guide