Installing Auxiliary Relays

There can be a maximum of three standard auxiliary relays installed in the SVRS
Alarm power center. Relays must be installed at the site. All SVRS Alarm high
voltage double pole relays are rated at 3HP/30A at 240 VAC (1½ HP/30A at
120 VAC). There is one relay provided with the SVRS Alarm kit. Other relays
can be ordered separately.
Relay locations
A standard relay can be installed in any one of the three locations provided in the
SVRS Alarm power center.
Emergency Shut-Off
Switch (ESO3) circuit
board (optional)
Standard relay
(Location 1)
Installing Relays
To install a standard relay in the SVRS Alarm Power Center:
1. Standard relay (Location 1): Position the relay coil up in the
relay compartment at about a 30° angle. Slide the tip of the relay
flange under head of the left-side screw. Rotate the relay upward
to align the right-side flange with the screw hole. Using a 1/4 in nut
driver, secure the relay in place with the retaining screw.
Standard relay
(Location 2)
SVRS Audible Alarm Installation and User's Guide
25
Slot for relay cables
Standard or
2-Speed relay
(Location 3)
Three ½"conduit
knockouts for
relay wires
(14 minimum to 6
maximum
depending on the
load)