Required Action For Svrs Blockage Event - Pentair SunTouch Installation And User Manual

Safety vacuum release system (svrs) audible alarm for use with intelliflo vs+ svrs and intellipro vs+ svrs pumps
Table of Contents

Advertisement

Required Action for SVRS blockage Event

(Schedule Mode, SVRS Auto Restart "Disabled")
IMPORTANT NOTE: Disabling the "SVRS Auto Restart" setting does not mean
that the SVRS suction blockage feature is also being disabled. When the pump
stops due to a SVRS blockage alarm, after the blockage has been removed,
pressing the Reset/Restart button on the SVRS Alarm control panel will "Soft
Prime" restart the pump after a five (5) second countdown, then the pump will
resume normal operations. During the soft prime the pump starts at the minimum
RPM setting of the pump and slowly ramps up to the desired speed setting.
System Normal
1520 rpm 340 Watt
Pump Stopped: SVRS audible alarm ON (due to drain blockage).
Check for blockage in pool/spa main drain.
Remove blockage.
Press Reset/Restart button once to deactivate alarm (alarm OFF).
Soft Restart in
5 Seconds
Check for Drain
!!! Blockage !!!
System Normal
1520 rpm 340 Watt
Required Action for SVRS blockage Event
(Schedule Mode, SVRS Auto Restart "Enabled")
IMPORTANT NOTE: If the "SVRS Auto Restart" is enabled and a SVRS blockage
event occurs, after the blockage is removed, pressing the Reset/Restart button
on the SVRS Alarm control panel will "Soft Prime" restart the pump in the
countdown set by the "SVRS Auto Restart" setting. The default setting is two (2)
minutes (can be set from 30 sec. to 5 mins.). During the soft prime the pump
starts at the minimum RPM setting of the pump and slowly ramps up to the
desired speed setting. If it senses a blockage it will stop and soft prime again.
The pump will repeat this process ten (10) times.
If a SVRS blockage event occurs, the SVRS Audible Alarm activates the alarm. A
blockage event can be caused by leaves, jewelry, hair, limb, or body caught in the
opening of the suction outlet cover. Take the following action if the SVRS alarm is
activated due to an SVRS blockage. The following screens are displayed after an
SVRS blockage occurs:
Note: To Enable/Disable "SVRS Auto Restart" pump setting, see page 10.
Pump in "Schedule" mode and "Auto Restart"
feature "Disabled".
Note: To Enable/Disable "SVRS Auto Restart" pump setting,
see page 10.
After a five (5) second countdown the pump
will restart in "Soft Prime" mode.
The display toggles between these two alert
messages.
The system returns to normal operation
(after blockage is removed)