Intelliflo Vs+ Svrs And Intellipro Vs+ Svrs Pump Overview - Pentair SunTouch Installation And User Manual

Safety vacuum release system (svrs) audible alarm for use with intelliflo vs+ svrs and intellipro vs+ svrs pumps
Table of Contents

Advertisement

11

IntelliFlo VS+ SVRS and IntelliPro VS+ SVRS Pump Overview

The IntelliFlo VS+ SVRS and IntelliPro VS+ SVRS variable speed pump with the
safety vacuum release system (SVRS) protection feature operates at a maximum
system flow rate of up to 174 gallons per minute (GPM). The pump can operate
from 1100 RPM to 3450 RPM with preset speeds of 1100, 1500, 2350 and 3110
RPM. The pump can be adjusted from the pump's control panel to run at any
speed between 1100 RPM to 3450 RPM for different applications. The pump
control panel alarm LED and error messages warn the user against under and
over voltage, high temperature, over current, suction blockage and freeze
protection with user defined minimum and maximum speed presets.
The IntelliFlo VS+ SVRS and IntelliPro VS+ SVRS pump may not protect
individuals from hair entrapment, limb entrapment or evisceration. The operator
must ensure that all suction and return fittings are clean and unobstructed
whenever the pump is started. Because SVRS protection is not enabled
during priming mode, never allow anyone in the pool during priming
mode. If SVRS auto restart is enabled and an SVRS event occurs, the pump is
allowed to restart automatically after the preset time period.
Note: The operator must insure that any SVRS blockage event is quickly
evaluated to confirm that all suction and return fittings are clean and
unobstructed. When the pump restarts after a high vacuum event it will slowly
ramp up to speed. If the pump senses a blockage it will shut down. The pump
will attempt to soft prime 10 times before attempting a full prime.
SVRS Audible Alarm Installation and User's Guide