Mounting The Eso3; Installing The Eso3 Circuit Board - Pentair SunTouch Installation And User Manual

Safety vacuum release system (svrs) audible alarm for use with intelliflo vs+ svrs and intellipro vs+ svrs pumps
Table of Contents

Advertisement

22

Mounting the ESO3

Select a convenient location to mount the Emergency Shut-Off switch (ESO3)
near the SVRS audible alarm. Provide a UL-Listed double-gang electrical outlet
box. The electrical box must be rated for outdoor/wet location use if the ESO3 is
located outside.

Installing the ESO3 Circuit Board

To access the SVRS Alarm Power Center electronics compartment:
Important Safety Instructions - When installing and using this electrical
equipment, basic safety precautions should always be followed. Before installing
the Emergency Shut-Off Switch, read all safety information on
page ii - v.
1. Switch the main power OFF to the SVRS Alarm power center.
2. Unlatch the front door,
3. Loosen the retaining screw on the front panel. Open the hinged
front panel to access the electronics compartment.
4. Mount the Emergency Shut-off Switch circuit board on the two
mounting studs. Secure the circuit board with the two retaining
screws.
ESO3 circuit
board
Mounting
studs
SVRS Audible Alarm Installation and User's Guide
SVRS Alarm Power Center
Emergency
shut-off
(ESO3)
circuit
board

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents