Connecting the ESO3 Switch to the Circuit Board (see Figure 3)
7. Connecting the ESO3 switch: Route a two-wire cable (sold
separately) through grommet located on the left-side of the SVRS
Alarm power center, up into the low voltage raceway to the ESO3
switch circuit board.
8. Connect the two wires to J13 on the ESO3 switch circuit board.
Connect the other end of the cable to the ESO3 switch plate as
shown below in figure 3.
Note: Use same polarity; (+ positive to positive),
(- negative to negative) when connecting the two wires from the
ESO3 circuit board to the ESO3 switch plate.
9. Verify that all cable connections are connected correctly. Close the
front panel and secure it with the retaining screw.
A
B
C
D
E
J13
F
2-wire connection
Note: see
EMERGENCY SHUT-OFF
back of
ESO3 for
wire
polarity
(+ -)
Emergency Shut-Off switch (ESO)
SVRS Audible Alarm Installation and User's Guide
Emergency shut-off
(ESO3) circuit board
A
B
C
SHUT OFF
+ -
D
+
-
E
F
+ -
Note: Use same polarity;
PUSH TO ALARM
(+ positive to positive),
(- negative to negative)
when connecting the two wires
PULL TO RESET
from the ESO3 circuit board to
the ESO3 switch plate.
Figure 3