Pentair SunTouch Installation And User Manual page 34

Safety vacuum release system (svrs) audible alarm for use with intelliflo vs+ svrs and intellipro vs+ svrs pumps
Table of Contents

Advertisement

26
Standard relay (Location 2): Position the relay (coil facing upward) in the
relay compartment at about a 30° angle. Slide the tip of relay flange under
head of the left-side screw. Rotate the relay downward to align the right-side
flange with the screw hole. Using a 1/4 in nut driver, secure the relay in place
with the retaining screw.
Relay Test button (if present): For testing relay connectivity, with power
applied, press the lever on the side (line/load side) of the relay.
Screw head
Line 1/Load 1
Line 2/Load 2
Standard relay (Location 3): Position the relay
(coil facing upward) on top of the mounting studs.
Align the relay flanges with the screw holes. Using
a 1/4 in nut driver, secure the relay in place with the
two retaining screw.
SVRS Audible Alarm Installation and User's Guide
Flange
Relay (Location 1)
Test button
Relay (Location 2)
Mounting studs for
relay screws