Sprinkler System/Drum Cleaning Of Sprinkler Nozzle - Fayat Group DYNAPAC CC1300 Translation Of Original Instruction Manual

Table of Contents

Advertisement

Fig. Pump system
1. Water filter
2. Stop cock
3. Water pump
1
3
Figure. Nozzle
1. Nozzle
2. Gasket
3. Filter
84
When cleaning the coarse filter (1), open the cock (2)
3
and loosen the filter housing.
Clean the filter and filter housing. Check that the
rubber gasket in the filter housing is intact.
1
After inspecting and carrying out any necessary
cleaning, start the system and check that it works.
2
A drain cock is placed on the left side of the pump
system area. This can be used to drain the tank and
the pump system.
Sprinkler system/Drum
Cleaning of sprinkler nozzle
Dismantle the blocked nozzle by hand.
Blow the nozzle (1) and fine filter (3) clean using
compressed air. Alternatively, fit replacement parts
and clean the blocked parts later on.
Nozzle
Nozzle
2
Standard
Standard
Option
Option
Option
Option
Option
Option
After inspecting and carrying out any necessary
cleaning, start the system and check that it works.
4812162001_D.pdf
Maintenance, 10h
Colour
Colour
l/min (at 2.0
l/min (at 2.0
bar)
bar)
yellow
yellow
0.63
0.63
blue
blue
0.98
0.98
red
red
1.31
1.31
brown
brown
1.63
1.63
Wear protective goggles when working with
Wear protective goggles when working with
compressed air.
compressed air.
gal/min (at
gal/min (at
40 psi)
40 psi)
0.20
0.20
0.30
0.30
0.40
0.40
0.50
0.50