Installing The Rubber Feet; Guidelines For Installation On A Flat Surface - Enterasys SecureStack C3K122-24 Hardware Installation Manual

Gigabit ethernet switch
Hide thumbs Also See for SecureStack C3K122-24:
Table of Contents

Advertisement

Installing the C3K Switch

Installing the Rubber Feet

The rubber feet provided with your switch provide ventilation to the switch and prevent surface 
scratching. Enterasys Networks recommends installing the provided rubber feet when not 
mounting to a standard 19‐inch rack, as the provided rubber feet may interfere with clearance of 
switch when installing in the rack. 
To install the rubber feet:
1.
Place the switch on its back on a sturdy flat surface to gain access to the bottom of the chassis. 
2.
Remove the four rubber feet from their plastic bag in the shipping box.
3.
Locate the four marked locations on the bottom four corners of the chassis. 
4.
Remove the protective strip from the back of one rubber foot and position it on a marked 
location and press firmly into place. Repeat this procedure to install the remaining three 
rubber feet in the other three locations.
5.
After installing the rubber feet, return the switch to its upright position.
6.
Proceed to Guidelines for Installation on a Flat Surface. 

Guidelines for Installation on a Flat Surface

Locate the switch within 152 cm (5 ft) of its power source and on a surface as shown in Figure
If an optional redundant power system is going to be installed and connected to the 14‐pin 
Redundant Power Supply input connector on the rear of the switch, refer to the installation guide 
shipped with the redundant power system. 
The next step to install the switch is dependent on the type of installation. If installing several 
switches in a stack, proceed to "Connecting High‐Speed Stacking Cables" on page 2‐13. If 
installing the switch as a standalone device, proceed to "Connect AC and RPS Power" on 
page 2‐17 for power connection instructions.
2-10 Hardware Installation
Note: If a number of switches are being installed in a stack, repeat steps 1 through 4 to
install the rubber feet on each switch before continuing with the installation.
Caution: To ensure proper ventilation and prevent overheating, leave a minimum
clearance space of 5.1 cm (2.0 in) at the left, right, and rear of the switch.
Precaución: Para asegurar una buena ventilación y evitar que el sistema se
sobrecaliente, deje un espacio mínimo de 5.1 cm (2 pulgadas) con respecto a los lados y
a la parte posterior del aparato.
Note: Do not connect the switch to the AC power source until instructed to do so later in the
installation process.