Using LANVIEW
Table 3-1 LANVIEW LEDs (continued)
LED
Color
State
Manager
Off
Switch is operating as a Member in the stack.
Green
Solid. Switch is operating as the Manager of the
stack.
RPS
Off
RPS not in use.
Internal power supply failure.
Amber
Solid. The switch internal power supply failed,
and the RPS is providing the proper power to the
switch.
Link/
Off
1.
Activity
2.
Green
Solid. Port is linked, but the interface is not
receiving any traffic.
Blinking. Port is linked and traffic is being
received or transmitted by the interface.
3-4 Troubleshooting
No link.
No activity or port in standby.
Recommended Action
None.
None.
None.
If an RPS is connected to the switch and
should be providing power, perform the
following:
1.
Ensure the RPS is powered on.
2.
Ensure that the AC power cord to the
RPS is plugged in correctly and that
there is power at the AC power
source.
3.
Replace the power cord with a known
good one.
4.
Ensure the DC power cord from the
RPS to the switch is plugged in
correctly.
5.
If the problem persists, contact
Enterasys Networks for technical
support.
None.
None.
None.