Connecting to the Network

Connecting Fiber-Optic Cables to LC Ports

This section describes how to connect 
a multimode fiber‐optic connection from the network or devices to an LC port connector of a 
Mini‐GBIC or XFP, or 
a single‐mode fiber‐optic connection from the network or devices to an LC port connector of a 
Mini‐GBIC or XFP.
Each fiber‐optic link consists of two fiber‐optic strands within the cable:
Transmit (TX)
Receive (RX)
The transmit strand from a device port connects to the receive port of a fiber‐optic Gigabit 
Ethernet device at the other end of the segment. The receive strand of the applicable LC port 
connects to the transmit port of the fiber‐optic Gigabit Ethernet device.
Enterasys recommends labeling fiber‐optic cables to indicate receive and transmit ends. Many 
cables are pre‐labeled, providing matching labels or tapes at both ends of each strand of cable.
To connect an LC cable connector to a fixed LC connector, refer to Figure
follows:
1.
Remove the protective covers (not shown) from the front panel LC fiber‐optic port and from 
the connectors on each end of the cable.
2-26 Hardware Installation
Warning: Fiber-optic XFPs/Mini-GBICs use Class 1 lasers. Do not use optical instruments
to view the laser output. The use of optical instruments to view laser output increases eye
hazard. When viewing the output optical port, power must be removed from the network
adapter.
Advertencia: Los XFPs/Mini-GBICs de fibra optica usan lasers de clase 1. No se debe
usar instrumentos opticos para ver la potencia laser. El uso de los instrumentos opticos
para ver la potencia laser incrementa el riesgo a los ojos. Cuando vean el puerto de la
potencia optica, la corriente debe ser removida del adaptador de la red.
Warnhinweis: XFPs/Mini-GBICs mit Fiber-Optik Technologie benutzen Laser der Klasse
1. Benutzen sie keinesfalls optische Hilfsmittel, um die Funktion des Lasers zu überprüfen.
Solche Hilfsmittel erhöhen die Gefahr von Sehschäden. Wenn sie den optischen Port
überprüfen möchten stellen Sie sicher, dass die Komponente von der
Spannungsversorgung getrennt ist.
Caution: Do not touch the ends of the fiber-optic strands, and do not let the ends come in
contact with dust, dirt, or other contaminants. Contamination of cable ends causes
problems in data transmissions. If the ends of the fiber-optic strands become
contaminated, use a canned duster to blow the surfaces clean. A fiber-port cleaning swab
saturated with optical-grade isopropyl alcohol may also be used to clean the ends.
Precaución: No toque los extremos de los cables de fibra óptica y evite su contacto con el
polvo, la suciedad o con cualquier otro contaminante. Si los extremos de los cables se
ensucian, es posible que la transmisión de datos se vea afectada. Si nota que los
extremos de los cables de fibra óptica se ensucian, utilice aire comprimido para limpiarlos.
También puede limpiarlos con un estropajo embebido en alcohol isopropílico.
Note: Leave the protective covers in place when the connectors are not in use to prevent
contamination.