Table A-22 Recommended Cable Types and Specifications
Item
10GBASE-LR-XFP
10GBASE-ER-XFP
10GBASE-ZR-XFP
10GBASE-SR-XFP
10GBASE-CX4-XFP CX4 TwinAxial
1. The limiting factor is saturation of the receiver by the transmitter. When presented with a signal at a strength
above the saturation point, the receiver cannot distinguish between pulses, though no hardware damage
occurs.
2. Links longer than 30 km for the same link power budget are considered engineered links. Attenuation for such
links needs to be less than the minimum

Console Port Pinout Assignments

The Console port is a DB9 serial communications port for local access to Local Management. Refer 
to Figure A‐1 for the Console port pin assignments. For more information, see "Connecting to 
Console Port for Local Management" on page 2‐19.
Figure A-1
1
Pin 2, Received Data (input)
2
Pin 3, Transmitted Data (output)
Type
SMF (Single Mode Fiber)
SMF (Single Mode Fiber)
SMF (Single Mode Fiber)
MMF (Multimode Fiber)
Console Port Pinout Assignments
Max. Reach
10 km (6.21 mi)
2
40 km (24.85 mi)
80 km (49.7 mi)
300 m (984 ft)
15 m (49.21 ft)
Â
Á
À
3
Pin 5, Signal Ground
All other pins not connected.
SecureStack C3K Hardware Installation Guide A-11
Console Port Pinout Assignments
1
Connector
Min. Reach
2 m (6.6 ft)
LC
2 m (6.6 ft) with
LC
minimum of 5 dB
attenuation
2 m (6.6 ft) with
LC
minimum of 11 dB
attenuation
2 m (6.6 ft)
LC
N/A
CX4