ACM8CB Access Power Controller Module:
• Eight (8) independently trigger controlled outputs. Output options:
a) Eight (8) Fail-Safe filtered power outputs.
b) Eight (8) Fail-Secure filtered power outputs.
c) Any combination of the above.
• Eight (8) Access Control System trigger inputs. Input trigger options:
a) Eight (8) normally open (NO) dry trigger inputs.
b) Eight (8) open collector inputs.
c) Any combination of the above.
• Eight (8) unswitched filtered aux. power outputs (outputs are rated @ 2.5A).
• Red LEDs on ACM8CB board indicate individual outputs are triggered (relays energized).
• Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
Fire Alarm disconnect input trigger options:
a) Normally open (NO) or normally closed (NC) dry trigger input.
b) Polarity reversal input from FACP signaling circuit.
• Green LED on ACM8CB board indicates FACP disconnect is triggered.
• FACP output relay indicates that FACP input is triggered
(form "C" contact rated @ 1A/28VDC, not evaluated by UL).
• Power supply output is factory installed to the ACM8CB board input.
It provides common power for ACM8CB board and all connected access control devices.
• ACM8CB board main fuses are rated @ 10A. Output PTCs are rated @ 2.5A.
eFlow Power Supply/Charger:
• Input: 120VAC, 60Hz.
• For output voltage and supply current refer to eFlowNA8D Series Configuration Chart, pg. 2.
• Auxiliary Power-Limited output rated @ 1A (unswitched).
• Overvoltage protection.
• Built-in charger for sealed lead acid or gel type batteries.
• Maximum charge current 1.54A.
• Automatic switch over to stand-by battery when AC fails.
Transfer to stand-by battery power is instantaneous with no interruption.
• Supervised Fire Alarm disconnect (latching or non-latching) 10K EOL resistor.
Operates on a normally open (NO) or normally closed (NC) trigger.
• AC fail supervision (form "C" contacts).
• Battery fail and presence supervision (form "C" contacts).
• Low power shutdown. Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units
and 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.
• For fuse rating, refer to eFlowNA8D Series Configuration Chart, pg. 2.
• Green AC Power LED indicates 120VAC present.
• AC input and DC output LED indicators.
• Short circuit and overload protection.
• Enclosure accommodates up to two (2) 12AH batteries.
Enclosure dimensions: 15.5" x 12" x 4.5" (393.7mm x 304.8mm x 114.3mm).

Power Supply Board Stand-by Battery Specifications:

Battery
eFlow4NA8D
7AH
30 Mins./4A*
12AH
35 Mins./4A*
40AH
Over 4 Hours/4A*
65AH
Over 4 Hours/4A*
*Only these configurations can be utilized in ULC-S319 installations.
eFlowNA8D Series Installation Guide
Specifications:
eFlow6NA8D
10 Mins./6A
30 Mins./6A*
Over 4 Hours/6A*
Over 4 Hours/6A*
eFlow102NA8D
5 Mins./10A
30 Mins./10A*
Over 2 Hours/10A*
Over 4 Hours/10A*
eFlow104NA8D
5 Mins./10A
30 Mins./10A*
Over 2 Hours/10A*
Over 4 Hours/10A*
- 3 -