To assign a new password, start at the Main Menu, select Management Setup Menu /Console
Login Configuration, and enter a new password for the administrator. Passwords can consist of up
to 11 alphanumeric characters and are not case sensitive.
NOTE: A user is allowed three attempts to enter the correct password; on the third
failed attempt, the current connection is terminated.
3.4

FACTORY DEFAULTS

Table 3-1
lists the default settings for switch configuration parameters. Each parameter can be
changed via the console menus or Telnet.
Table 3-1 Factory Default Settings
Parameter
Multicast Filtering
IGMP Multicast Filtering
Port Configuration
Speed and Duplex
Admin
Port Priority
Default Ingress User Priority
Spanning Tree Algorithm
Active Aging Time
Bridge Priority
Forward Delay
Hello Time
Max Age
Path Cost
Port Priority
Spanning Tree Protocol
Default Value
Disabled
Auto
Enabled
0
300
32768
15
2
20
4 - 1000 Mbps ports
9 - 100 Mbps ports
100 - 10 Mbps ports
128