Alarm - Schedule Page; Rvrc Page - NetVu TransVu 3 Installation Manual

Table of Contents

Advertisement

Title TransVu 3 DVR Installation Manual
Pixel Change (%): Percentage value of the overall change required, over the complete range
of black to white, to be included in the pixel count. A 100% pixel change would be from
black to peak white. Default is 20%.
To create a VMD zone:
1. Select the desired zone.
2. Position the mouse pointer at the top left-hand corner of the zone and then left click.
3. Move the mouse to the bottom right-hand corner of the zone and then right click.
A rectangle will then be displayed based on these two selected points.
Clicking Reload Img (Red) will reload the image behind the grid editor.
Clicking Clear All (Green) will clear (i.e. de-select) all the zones in the grid editor.
Clicking Default Grid (Yellow) will create 16 equally sized zones in a 4 x 4 grid with zone 1 in the
top left-hand corner and zone 16 in the bottom right-hand corner.
Click the Save button when you have finished, in order to save the changes that you have made.
Alarm – Schedule page
The page configures how the unit will move between two modes, SET and UNSET.
Using these two modes the unit can respond to the same stimuli (alarms, VMD etc.) in different
ways, depending on whether the TransVu is SET or UNSET.

RVRC page

This page allows the SET/UNSET status of the unit to be remotely overridden for a set period of
time.