Audio Recording: When Enabled, this will record all audio received by the unit to the HDD.
Please note, enabling this option will reduce the record duration.
Record uncompressed: Select this option to record audio in an uncompressed format, note that
this will significantly increase the disk space used.
Playback Volume: This is the volume setting for local audio playback.

Power Management Page

The power management page is used to enable power management and to configure the power
management settings of the unit.
Power Management: Enables or disables power management in the unit.
Caddy Keyswitch: When enabled, opening the hard disk caddy keyswitch will disable recording so
that the hard disk may be removed safely.
Ignition Enabled: Enables or disables ignition sensing, so that when ignition is off recording will
cease after the Ignition Off Timeout Period.
Ignition Off Timeout: Sets the time in seconds after which recording will stop after the ignition is
turned off.
Low Supply Timeout: Sets the time in seconds after which recording will stop if the supply voltage
falls below the minimum supply voltage level
Minimum Supply: Sets the minimum supply voltage level in volts.