Alarm Inputs

Three analogue alarm inputs are available which can be configured via the web pages as follows:
Normally open contact
Normally closed contact
Tamper detect
1
20

Serial Port

COM1 is a three wire RS232 port which defaults to the debug function.
1
20
1
6
1
Alarm recognised when a short circuit to 0V is applied
Alarm recognised when input is open circuit
If a detector is configured with end of line (EOL) resistors four
detector states can be detected, no activity, alarm, tamper (open
circuit), tamper (short circuit)
P28 Alm Gnd
P29 Alm Input 2
Baud
Data
Parity
Stop
Flow control
P11 RS232 TXD
red
P31 RS232 RXD
orange
P32 RS232 Gnd
black
5
9
P15 Alm Input 3
P14 Alm Input 1
38400
8
0
1
none
19