Keypad Operation And Parameters; Keypad Operation - Parker FL20-CA Series Product Manual

Table of Contents

Advertisement

V. Keypad Operation and Parameters

5.1 Keypad operation

5.1.1 Keypad description
The name of keypad and each part as figure below:
SON
MODE
Identifier
Name
Indicator
SON
Indicating that Servo is on.(Light on when servo on)
(green)
Indicator
ALM
Indicating that malfunction occurs.(Light on when faulty occurs)
(red)
EtherCAT
RUN
EtherCAT state machine indicator
state indicator
The LCD display (5-digit display panel) shows the monitor codes,
PANAL
LCD Display
parameter settings and operation values of the servo drive.
1 Switching between function groups.
MODE
Mode key
2 Displaying malfunction codes in turn.
1 Press the key to increase the displayed value.
2 Hold the key for 0.5s to increase setting the value slowly.
UP
(UP)
3 Hold the key for over 1s to increase setting value rapidly.
4 Used to forward start in jogging run.
1 Press the key to decrease the display value.
2 Hold the key for 0.5s to decrease setting value slowly.
DOWN
(DOWN)
3 Hold the key for over 1s to decrease setting value rapidly.
4 Used to reverse start in jogging run.
1 Hold the key for 0.5s to enter into parameter setting mode
2 Pressing the key can move the cursor to the left and then change
parameter settings (blinking digits) by using arrow keys.
shift/set
(SET)
3 Hold the key for 0.5s to confirm and set current value into the
current user parameter.
4 Hold the key for 2s to reset the malfunction.
FL20-CA Series
Fig 5.1.1 Keypad sketch map
Function
83
RUN
ALM
显示器
LCD display
四个可操作按键
Four operating keys
四个按键标识符
Four key identifiers

Advertisement

Table of Contents
loading

Table of Contents