Function description
I/O data name
SDIM_PosDeactivateSS1M
SDIM_NegDeactivateSS1M
O-data type: FS_O_EI_CONTROL
I/O data name
BasicInterface
BasicInterface
BasicInterface
BasicInterface
O-data type: FS_O_EI_REFPOS
I/O data name
SetSDIM
SetSDIM
SetSOSM
SetSOSM
O-data type: FS_O_EI_SSR_PARA
I/O data name
SSR_Parameter
SSR_Parameter
SSR_Parameter
Operating Manual PSSu K F EI CV(-T)
1004290-EN-04
I/O data element
Data: SAFEBOOL
Data: SAFEBOOL
I/O data element
ActivateCascading:
BOOL
Alive: SAFEBOOL
ErrorAcknowledgement:
BOOL
Restart: SAFEBOOL
I/O data element
Set: SAFEBOOL
Alive: SAFEBOOL
Set: SAFEBOOL
Alive: SAFEBOOL
I/O data element
Alive: SAFEBOOL
MaxSpeed: SAFEWORD Maximum speed for Safe Speed Range Monitor-
MinSpeed: SAFEWORD
Meaning
TRUE: Deactivate monitoring function SDIM-Pos
for the positive direction for the outputs.
FALSE: Activate monitoring function SDIM-Pos
for the positive direction for the outputs.
TRUE: Deactivate monitoring function SDIM-Neg
for the negative direction for the outputs.
FALSE: Activate monitoring function SDIM-Neg
for the negative direction for the outputs.
Meaning
TRUE: Enable cascading output.
FALSE: Switch off cascading output.
Only used internally
TRUE: Reset error
TRUE: Reset restart interlock
Meaning
TRUE: Restart of monitoring functions SDIM
Only used internally
TRUE: Restart of monitoring functions SOSM
Only used internally
Meaning
Only used internally
ing (SSRM) and limit value for Safe Speed Monit-
oring 1 (SSM1) in compressed form.
Minimum speed for Safe Speed Range Monitor-
ing (SSRM) in compressed form