Function description
Proximity switch
combinations
NPN / PNP
PNP / NPN
}
Please note the values stated in the sensor's technical details.
}
For a full configuration, the maximum frequency of the sensors you are using must be
entered in PAS4000 (see sensor's data sheet).
4.11
Encoder
}
The following encoders can be used:
–
–
–
}
The encoders can be connected with or without Z index (0 index).
}
The cables used to connect the encoders must be shielded (see connection diagrams
in the chapter entitled "EMC-compliant wiring").
}
A pnp proximity switch can also be connected to track Z for monitoring broken shear-
pins.
Please note:
Monitoring for broken shearpins does not become active until
–
Operating Manual PSSu K F EI CV(-T)
1004290-EN-04
Signal image during movement
CAUTION!
Appropriate installation measures should be taken to prevent a foreign body
coming between the signal encoder and the proximity switch. If not, the for-
eign body could cause invalid signals.
TTL, HTL (single-ended or differential signals)
Sin/Cos 1 Vss
Hiperface®
The minimum speed has been exceeded and
Ini 1
Ini 2
> 1% of period length
Ini 1
Ini 2
> 1% of period length
De-energised
energised
energised
De-energised
energised
De-energised
De-energised
energised
34