Pilz PSSu K F EI CV Operating Manual page 22

Table of Contents

Advertisement

Function description
SOSM_Enable_SS1M
Legend
}
SetSOSM: Adopt reference position once the delay time has expired
}
SOSM_Enable:
}
Output on the module (SOSM_Enable_SS1-M):
}
t1: Delay time
Operating Manual PSSu K F EI CV(-T)
1004290-EN-04
s
,v
pos
neg
1
SetSOSM
0
1
SOSM_Enable
0
1
0
"1": Monitored limit value not violated/monitoring of standstill position
"0": Monitored limit value violated/monitoring inactive
"1": Monitored limit value not violated/monitoring of standstill position
"0": Monitored limit value violated/monitoring inactive
t1
t
22