CAUTION: THESE INSTRUCTIONS MUST
REMAIN WITH THE HOMEOWNER.
WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing property
damage, personal injury or loss of life.
– Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
– WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do
not use any phone in your building.
• Immediately call you gas supplier from
a neighbor's phone. Follow the gas
supplier's instruction.
• If you cannot reach your gas supplier,
call the fire department.
– Installation and service must be
performed by a qualfied installer,
service agency or the gas supplier.
– In the Commonwealth of
Massachusetts, a carbon monoxide (CO)
detector shall be installed in the same
room as the appliance.
Installation and

Operation Instructions

ATTENTION : CES INSTRUCTIONS DOIVENT
DEMUERER AVEC LE PROPRIÉTERE D'UNE
MAISON.
AVERTISSEMENT: Assurez-vous de bien
suivreles instructions données dans cette
notice pour réduire auninimum le risque
d'incendie ou d'explosion ou pour éviter tout
dommage matériel, toute blessure ou la mort.
– Ne pas entreposer ni utiliser d'essence ni
d'autres vapeurs ou liquides inflammables
dans le voisinage de cet appareil ou de tout
autre appareil.
– QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE
GAZ:
• Ne pas tenter d'allumer l'appareil.
• Ne touchez à aucum interrupteur. Ne pas
vous servir des téléphones se trouvant
dans le bâtiment où vous trouvez.
• Appelez immédiatement votre
fournisseur de gaz depuis un voisin. Suivez
les instructions du fournisseur.
• Si vou ne pouvez rejoindre le fournisseur
de gaz, appelez le service des incendies.
– L'installatione l'entretien doivent être
assurés par un installateur ou un service
d'entretien qualifié ou par le fournisseur
de gaz.
1

Advertisement

Table of Contents
loading

Summary of Contents for Jøtul GF 100 DV II

  • Page 1: Operation Instructions

    Installation and Operation Instructions ATTENTION : CES INSTRUCTIONS DOIVENT CAUTION: THESE INSTRUCTIONS MUST DEMUERER AVEC LE PROPRIÉTERE D’UNE REMAIN WITH THE HOMEOWNER. MAISON. AVERTISSEMENT: Assurez-vous de bien WARNING: If the information in these suivreles instructions données dans cette instructions is not followed exactly, a fire notice pour réduire auninimum le risque or explosion may result causing property d’incendie ou d’explosion ou pour éviter tout...
  • Page 3: Table Of Contents

    Table of Contents Specifications, Jøtul GF 100 DV II ..4 Specifications, Jøtul GF 200 DV II ..5 General Information ....... 6 Jøtul GF 100 DV II Nordic QT Service Tools ..........6 Jøtul GF 200 DV II Lillehammer Safety Information ........
  • Page 4: Specifications, Jøtul Gf 100 Dv Ii

    464 mm Weight: 150 lbs. 425 mm The Jøtul GF 100 DV II Nordic QT is a Direct Vent gas heater designed as a sealed combustion, air circulat- ing gas appliance for residential applications. This appliance is approved for installation using 6 5/8"...
  • Page 5: Specifications, Jøtul Gf 200 Dv Ii

    Jøtul GF 200 DV II Lillehammer Specifications 24 3/4” Input Rates 630 mm Natural Gas 20,000 BTU/hr. maximum input 11,400 BTU/hr. minimum input Propane 22 3/4” 18,000 BTU/hr. maximum input 560 mm 8,450 BTU/hr. minimum input Inlet Pressure: Natural Gas: 5.0 WC (1.24 kPa) 7.0 WC (1.74 kPa) Propane: 12.0 WC (2.98 kPa)
  • Page 6: General Information

    Simply lift it from the stove body. unsafe or hazardous installation, which may result in a fire, explosion, property damage, personal injury or loss GF 100 DV II ONLY : Remove the Front Plate. of life. Slide it straight up to disengage it from the Side Plates.
  • Page 7: Safety Information

    Location Safety Information In selecting a location for the stove, consider the Your stove will reach high surface temperatures following points: during normal operation. Please note the following 1) Heat distribution cautionary information. 2) Vent termination requirements 3) Gas supply line routing Due to the high operating temperatures, this 4) Traffic areas, furniture, draperies, etc.
  • Page 8: Mantel & Trim

    Ceiling: 42” (1066 mm) Corner: 2” (50 mm) Sides: 3” (76 mm) Minimum Clearances between Vent Pipe and Jøtul GF 100 DV II Jøtul GF 200 DV II Combustible Materials: Nordic QT Lillehammer Horizontal Run: A A A A A 50 in.
  • Page 9: Vent Requirements Adding Restriction

    Venting Requirements Intake Air Restriction Both stoves may be installed with a vertical or horizontal termination and must conform to the configuration You may need to restrict air intake to the burner, depend- requirements described in this section. This appliance is ing on the stove vent configuration.
  • Page 10: Clearances

    Vertical Vent Termination The Jøtul GF 100 DV II and Jøtul GF 200 DV II are ap- proved for vertical venting through a ceiling or to a roof termination following these guidelines: The termination should fall within the shaded area of the grid depicted in fig.7 below.
  • Page 11 MAINTAIN THE PROPER CLEARANCES TO COMBUSTIBLES AS DEFINED IN THIS MANUAL AND IN THE INSTRUCTIONS PROVIDED WITH EACH VENT COMPONENT. Figure 10. Simpson Dura-Vent #923GCL Co-linear Adaptor. GF 100 DV II: A : 16 3/4” B : 20 3/4” GF 200 DV II: A : 18”...
  • Page 12: Horizontal Termination

    Horizontal Vent Termination Wall Cut-out Opening: A minimum 10" X 10" (250 mm x 250 mm) square hole is required for proper pipe clearances through a combustible wall. Use one of the approved vent manufacturers’ WALL THIMBLE for the wall penetration. DO NOT FILL AIR SPACE WITH ANY TYPE OF INSULATION.
  • Page 13: Wall Shield Installation

    Wall Shield Installation The decorative Wall Shield, included in the Miscellaneous Hardware bag, is used to obscure the vent hole in the wall in installations vented directly off the rear of the stove. Follow this procedure: 1. Remove the top two 1/4” hex head screws from the rear shroud of the stove.
  • Page 14: Vent Terminal Clearances

    Horizontal Termination Clearance Figure 17. Vent Terminal Clearances - National Fuel Gas Code. A = Clearance above grade, veranda, porch , deck, or H = *Not to be installed within 15 feet (4.5 m) above a balcony : 12 inches (30 cm) minimum. meter/regulator assembly within 3 feet (90 cm) horizontally from the center-line of the regulator.
  • Page 15: Mobile Home Installation

    Mobile Home Installation Fuel Conversion Your gas stove is shipped from the factory equipped to These appliances can be installed for use in a mobile burn NATURAL GAS only. If PROPANE gas is to be used as home in the U.S. and Canada provided: fuel, the appliance must first be converted for use with 1.
  • Page 16 2. Remove the stove Top Plate (3). 15. Apply gas to the system and check for leaks using a 3. GF 100 DV II Only: Remove the front plate from the soapy water solution or electronic gas detector. stove. Pull the casting straight up and out away from NEVER USE AN OPEN FLAME TO CHECK FOR GAS the side panels.
  • Page 17: Gas Supply Connection

    Gas Supply Connection Pilot Head NOT T T T T E: E: E: E: E: If If If If If the optional Blo the optional Blo the optional Blo the optional Blow w w w w er will be installed, er will be installed, er will be installed, er will be installed, use a...
  • Page 18: Gas Pressure

    The GF 100 DV II Nordic QT does not require adjustment Pressure Test: Attach a manometer to the appropriate test point on the valve. See fig. 24. The gauge connections for elevations up to 4500 ft.
  • Page 19: Air Shutter Adjustment

    Flame Appearance - Air Shutter Adjustment WARNING: AIR SHUTTER ADJUSTMENTS SHOULD ONLY BE High Altitude Orifice Chart PERFORMED BY A QUALIFIED PROFESSIONAL SERVICE Jøtul GF 200 DV II Only TECHNICIAN. The air shutter setting at the burner orifice can be ad- Orifice Elevation Fuel...
  • Page 20: Wall Thermostat

    Optional Wall Thermostat or Log Set Installation Remote Control NOTE: Install the optional Brick Kit, if appropriate, before Use only a 750 millivolt DC two-wire circuit thermostat installing the Log Set. See page 30. with this appliance. The thermostat should be placed in the same room as the heater, typically 5 feet off the The Log Set and Ember Stones are packaged in foam floor.
  • Page 21: System Check

    System Check 1. PURGING THE GAS LINE: When lighting the appli- ance for the first time, it will take a few moments to clear the gas line of air. Once this purge is complete, the appliance will operate as described in the lighting instructions.
  • Page 22: Operation

    Operation Familiarize yourself with the controls of your stove. Make sure that anyone else using the appliance is also familiar with the controls and operation procedures. Always follow the Lighting Instructions on the inside back cover of this manual and also located on the Rating Plate attached to the burner assembly.
  • Page 23 Glass and Gasket Replacement Enamel Care and Maintenance Only Use Replacement Kit 155599. 1. Use a small screwdriver to pry the four retainer clips off • Do not attempt to clean hot enamel surfaces. Clean of the glass frame. See fig. 33. only cold surfaces with a soft damp cloth and polish with a clean dry cloth.
  • Page 24: Optional Blower

    Optional Blower # 155631 C C C C C on onten tents ts ts ts ts T T T T T ools R ools R ools R ools Requir ools R equir equir equir equired 1. Blower • 1/4” socket driver CONNECT THE GAS SUPPLY TO THE 2.
  • Page 25: Blower Operation

    Hex Bolts 4. Attach the Blower to the stove. BLOWER GF 100 DV II: First install the Mounting Bracket to the holes in the bottom of the rear shroud using two #8 x 1/2” sheet metal screws. Then attach the Blower to the Mounting Bracket using the two M6 flange head hex bolts as shown in fig.
  • Page 26 GF 100 DV II / GF 200 DV II Illustrated Parts Breakdown / Firebox Assembly Figure 39.
  • Page 27 Parts List - GF 100 DV II / GF 200 DV II Firebox Assembly Part Description Part Number Part Description Part Number Rear Shroud, Matte Black ....22055592 Middle Log..........221105 Rear Shroud, Jøtul Iron ....22055585 Rear Log, (two-piece) ......221104 Burner Control Switch ......
  • Page 28: Illustrated Parts Breakdown

    Illustrated Parts Breakdown / Cast Iron and Associated Hardware Jøtul GF 100 DV II Nordic QT Figure 40 . Jøtul GF 200 DV II Lillehammer Figure 41.
  • Page 29: Fuel Conversion Kit - Lp

    Cast Iron Parts List Jøtul GF 100 DV II Nordic QT Cast Iron Parts Matte Black Blue Black Ivory Green Jøtul Iron Jøtul Iron Majolica Majolica Paint Enamel Enamel Enamel Paint Enamel Brown Enamel Blue Enamel Top Casting 10391092 10391027...
  • Page 30: Addendum - Brick Panel Kit

    1. Remove the Top Plate. Simply lift it up off of the stove body. It is not fastened. 2. GF 100 DV II ONLY: Remove the Front Plate by lifting straight up to disengage it from the sides. 3. Remove the Glass Frame. Disengage the two trunk...
  • Page 31: Lighting Instructions

    LIGHTING INSTRUCTIONS FOR YOUR SAFETY, READ BEFORE LIGHTING. WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. A. A. A. A. A. This appliance has a pilot which must be lit •...
  • Page 32 This appliance must be installed in conformance with local and national building regulations. Before beginning the installation, it is important that the these instructions be carefully read and understood. Jøtul maintains a policy of continual product development. Consequently, products may differ in specification, color or type of accessories from those illustrated or described in various publications.

This manual is also suitable for:

Gf 200 dv ii

Table of Contents