Maintenance Of The Sensors; Maintenance; Maintenance Of The System Prior To The Start Of The Season - ProMinent Splash Control 2 Assembly And Operating Instructions Manual

Swimming pool controller
Table of Contents

Advertisement

Maintenance and repair
Parameter
Electrical fuse
11.2
Maintenance of the sen‐
sors
pH and ORP sensors are maintenance-free
and need to be replaced when they are no
longer operating perfectly. Having said that, the
good physical state of the sensors needs to be
checked regularly.
1.
Check whether there is dirt or reside on
the heads of the sensors.
2.
Do so by regularly calibrating the
sensors and replace them when they
can no longer be calibrated.
3.
Remove the sensors during long opera‐
tional pauses (e.g. over-wintering) and
store the sensors in their original pack‐
aging. Do not forget to pour water, or
even better water from the pool, into the
sensor cover.
11.3

Maintenance

After extended periods of idleness
If the peristaltic pump has not pumped gaseous
or adhesive feed chemicals for a longer period
of time, checked whether the state of the hoses
permits reliable operation.
66
Specification(s)
Glass fuse, 5x20 , slow-acting, 3.15 A
Glass fuse, 5x20 , slow-acting, 250 mA
Approx. every six months
Checks:
Visual control of the liquid end
n
Check the pump hose for leak-tightness
n
Check the pump connectors for leak-tight‐
n
ness
Shorter maintenance intervals may be neces‐
sary depending on the feed chemicals used
and operating conditions.
Approx. annually
Replace the pump hose.
This can lead to a reduction in pump
capacity over time depending on the
operating conditions. Therefore replace
the pump hose earlier if necessary.
The power end is maintenance-free.
11.4
Maintenance of the
system prior to the start of
the season
User qualification: trained user
n
2.4 'User qualification' on page 15 .
Markings(s)
F2
F3
Ä Chapter

Advertisement

Table of Contents
loading